On the first cold, clear morning in November, a lot of Metro Vancouver bedrooms wake up to the same view: glass streaming, a puddle on the sill, and a grey line of mould starting in the corner of the frame. Window condensation in winter shows up in BC homes of every age, and most owners treat it as a window problem. Sometimes it is. About as often, the glass is fine and the house is holding more moisture than it can get rid of.
The difference matters because the two fixes are priced far apart. New windows on a typical house run $22,000 to $40,000, while better ventilation can cost a few hundred dollars, or a few thousand. Pick the wrong one and you can still find water on the sills in January.
Why do windows fog up in winter in BC homes?
Windows fog when the inside surface of the glass drops below the dew point of the room air. At 21°C and 50 percent relative humidity, the dew point is about 10°C. On a 0°C night, single glazing sits near 5°C and fogs. Older double glazing stays near 13°C in the centre but falls below 10°C at the bottom edge. The cause is cold glass (the envelope), wet air (ventilation), or usually some of both.
Two numbers decide whether a window fogs
Condensation happens where a surface temperature meets a humidity level. Change either one and the water stops.
The surface temperature depends on the window. With the room at 21°C and 0°C outside, the inside of the glass sits at roughly these temperatures, and the bottom edge starts to fog once indoor humidity passes the figure in the last column:
| Window type | Inside glass, centre | Inside glass, bottom edge | Edge fogs above |
|---|---|---|---|
| Single glazing, aluminum frame | about 5°C | about 4°C | 33% |
| Clear double glazing, aluminum spacer (1980s to 1990s) | about 13°C | 6 to 8°C | 40% |
| Low-e double glazing, argon, warm-edge spacer | about 17°C | 11 to 13°C | 55% |
| Low-e triple glazing | about 18 to 19°C | 14 to 15°C | 65% |
These are approximate, with blinds open and room air moving across the glass. In an Arctic outflow cold snap at minus 5, every threshold drops by 5 to 10 points. Close heavy curtains tight to the glass and the surface gets colder again, because the curtain keeps warm room air off it.
The humidity side comes from the people in the house. A family of four puts roughly 10 litres of water into the air every day through cooking, showers, breathing, and laundry. In a drafty 1970s house, outdoor air leaking in carries much of that away. In a tight house with no mechanical ventilation, it stays.
Owners on the coast often doubt that outdoor air can dry a house when it's raining. It can. Air at 5°C and 90 percent humidity holds about 6 grams of water per cubic metre. Warm that same air to 21°C indoors and its relative humidity falls to about 33 percent. Wet weather outside becomes dry air inside once it is heated, which is why ventilation works in a Lower Mainland January.
Envelope or ventilation: how to tell which one you have
You can usually sort this out in a week with a $25 digital hygrometer and some attention to where the water forms.
Put one hygrometer in the main living area and a second in the bedroom with the worst windows. Read both first thing in the morning, when window condensation peaks. If the bedroom reads above 55 percent on a cold morning, the house has a moisture or ventilation problem, and new windows will not cure it. If it reads 35 to 45 percent and the glass still streams, the windows are too cold for normal living. That points to the envelope.
Where the water sits tells you the rest:
- Across the whole pane of every window: humidity is high. Start with ventilation.
- A 2 to 5 cm band along the bottom of double-glazed units: the spacer at the edge is the coldest part of the glass. Expect it in a cold snap. If it appears every morning, humidity is on the high side for those windows.
- Worst in bedrooms in the morning, dry in the living room: two people slept behind a closed door with no fresh air supply. A local ventilation problem.
- Only behind blinds or curtains pulled tight to the glass: leave a gap at the bottom so room air can reach the window.
- Between the two panes: the sealed unit has failed. Humidity has nothing to do with it. The glass unit needs replacing, usually a few hundred dollars per window, and the frame can often stay.
- On the outside of the glass on a clear morning: the windows are working. Well-insulated glass loses so little heat that its outer pane cools below the dew point outside.
- Frost or water on aluminum frames while the glass stays clear: the frames have no thermal break. That is an envelope fix.
Rule out a leak before you blame condensation. Water on a sill can be rain coming past failed window flashing. Condensation forms on cold, clear mornings in most rooms at once. A leak shows up after wind-driven rain, on one side of the house, often at one corner of one window. If the stain under a window grows after a southeast storm, look at the window and door flashing. If it grows after a week of dry, cold weather, it is condensation.
The ventilation side: where most older BC houses fall short
Most BC houses built before the late 1990s were designed with no whole-house ventilation at all. They have a bathroom fan or two, a range hood, and air leaks. The fans are often the originals, loud enough that nobody runs them, and on a lot of older houses the bathroom duct ends in the attic instead of outside. That last one puts shower moisture on the underside of the roof sheathing every morning.
In order of cost, starting with free:
- Run the bathroom fan for 20 to 30 minutes after each shower, and the range hood whenever a pot is boiling. A hood that recirculates through a filter removes grease and leaves the moisture in the kitchen.
- Stop drying laundry on racks indoors. One load gives off 2 to 3 litres of water.
- Cover a dirt crawlspace floor with 6-mil polyethylene, lapped and taped at the seams. An open dirt crawlspace under a 1960s Burnaby bungalow can add several litres a day to the house.
- Replace old bathroom fans with quiet, continuous-rated fans (1 sone or less) on a humidity control, ducted outside. Expect $400 to $900 per fan installed in an existing ceiling.
For many houses, those steps bring morning humidity under 50 percent and clear most of the glass. When they don't, or when the house has been air sealed, the next step is a heat recovery ventilator (HRV). An HRV brings fresh air to bedrooms and living areas, exhausts stale air from bathrooms and the kitchen, and passes both airstreams through a core so the outgoing heat warms the incoming air.
The energy numbers on a 2,200 sq ft, three-bedroom house look like this. The house needs about 40 litres per second of fresh air through the winter. Pull that through exhaust fans and leaks, and the heat in the outgoing air is lost: roughly 3,400 kWh over a Lower Mainland heating season. An HRV recovering 75 percent of it keeps about 2,300 kWh a year after its own fan power. That is around $320 a year on electric baseboard at about 14 cents per kWh, or about 11 percent of the space heating in an older house that needs 21,000 kWh a year. On a heat pump, divide the dollar figure by two or three.
An HRV retrofit with new ducting in a finished house runs $6,000 to $10,000. Quiet continuous exhaust fans cost $1,500 to $3,000. On baseboard heat, the difference pays back in about 14 to 22 years on energy alone. People install HRVs for the air. Bedrooms stop smelling stale by morning, and the windows stay clear.
One choice trips up a lot of owners. An energy recovery ventilator (ERV) also returns moisture to the incoming air. In a dry Prairie winter that helps. In a Lower Mainland house that already fogs its windows, it holds on to the moisture you are trying to remove, so an HRV is usually the better unit here.
Ducting is the hard part of any HRV retrofit. Running supply ducts to each bedroom is far easier with ceilings open, so if an interior renovation is on the calendar, plan the HRV into it.
The envelope side: cold glass, cold frames, and the wall around them
If humidity sits at 35 to 45 percent and the windows still stream, the glass is too cold. Single-glazed aluminum sliders on 1970s Vancouver Specials in East Vancouver and South Burnaby are the classic case. The frame carries heat out so well that it frosts on a minus 5 night while the room is 21°C. Keeping those windows dry would mean holding the house below 25 percent humidity, which dries out skin and hardwood floors.
Low-e, argon-filled double glazing in fibreglass or vinyl frames with warm-edge spacers raises the inside glass temperature from about 5°C to about 17°C on a 0°C night. At the bottom edge, the fogging threshold moves from about 33 percent humidity to about 55 percent, which covers normal family life. Triple glazing pushes it to about 65 percent. Our guide to triple-glazed windows in BC covers when that step up is worth the extra cost.
The price of new windows is real: $22,000 to $40,000 for 18 to 22 windows on a typical house. They cut whole-house heat loss by 10 to 15 percent, which pays back slowly on the bill. What you are buying is condensation control and comfort near the glass. If a stucco or siding renovation is coming in the next few years, do the windows with it. The rough openings are exposed, the flashing gets rebuilt, and nobody has to cut new stucco back around each frame.
There is a second envelope problem you cannot see from inside the room. Warm indoor air leaks out through gaps around the window rough openings, electrical boxes, and top plates. When that air reaches cold sheathing, its moisture condenses inside the wall. The room looks dry. Years later the sheathing under the window corners is soft. When we strip stucco from older BC houses, some of the wettest sheathing sits under windows, and part of that water came from inside the house. Sealing the rough openings and every wall penetration during a re-clad stops it, and our article on air sealing an older BC home walks through the sequence.
Tightening the house without ventilating it
This catches owners after a good renovation. A drafty older house testing around 10 air changes per hour at 50 pascals (10 ACH50) leaks roughly 0.5 air changes per hour on an ordinary winter day. That is close to what a ventilation system would supply, and it is why many old houses never had a humidity problem despite having no fans worth the name.
Air seal that house down to 3 ACH50 and the natural air change drops to about 0.15 per hour. The family still showers and cooks the same amount. The moisture stays, and the first winter after an envelope renovation can bring more window condensation than the last winter before it, along with mould in closets on exterior walls.
The answer is to plan ventilation into any project that includes air sealing. The BC Energy Step Code assumes exactly that for new houses: a blower door test proves the house is tight, and Section 9.32 of the BC Building Code requires a mechanical ventilation system sized to the number of bedrooms. Renovations of existing houses mostly sit outside the Step Code, so on a typical re-clad nobody requires the ventilation. You have to ask for it.
Passive House takes the same logic to its limit. A certified Passive House tests at 0.6 ACH50 or less and runs an HRV that recovers at least 75 percent of the heat, with windows specified so the inside glass stays within a few degrees of room temperature on the coldest design day. Those houses rarely see condensation on the glass in winter. We are Passive House Certified, and what we carry from that work into ordinary renovations is one rule: when a house gets tighter, its surfaces need to get warmer and its ventilation has to be planned in the same scope.
Condos and townhouses
In most BC strata buildings, windows and exterior walls are common property, while the humidity inside each unit is the owner's. Councils hear condensation complaints every winter. A hygrometer reading settles most of them. A unit at 60 percent with blinds pulled tight has a ventilation problem the owner can fix. A building where every unit fogs at 40 percent has windows that belong in the depreciation report. When a strata replaces windows during an envelope project, a ventilation review in the same specification costs little and heads off the first-winter complaints described above.
When window condensation needs a contractor
A few foggy mornings during a cold snap, dry by noon, is normal in most BC homes. Call when you see any of these:
- Water running off the glass onto the sill most mornings from November to March
- Black mould on frames, drywall returns, or closet walls on exterior walls
- Peeling paint or soft wood on the sill or the wall below a window
- Staining on the exterior stucco or siding below window corners
MV Construction has completed 200+ renovations across Greater Vancouver and Vancouver Island over 17+ years. Our crews are fully licensed and WCB-insured, and our workmanship is warranty-backed. As a building envelope contractor, we look at the windows, the wall around them, and the ventilation together, and the written estimate prices each item on its own line: glass, air sealing, fans or an HRV.
If your windows fog up every winter, take a week of morning hygrometer readings and note which rooms are worst. Then call (778) 375-5672 or request a written estimate. We will check the glass, the frames, and the wall below them, and tell you whether the fix is windows, ventilation, or both.